Summa, transmission error troubleshooting

Ethernet connected:

Ethernet_Connection.png

Check if under Host in VisualCut the correct cutters IP address is entered.

Transmission errors are most of the time due to a network issue (assuming the cutter is connected through Ethernet)

Check if one gets a clear ping, How to ping

Consider for troubleshooting purposes a direct Ethernet connection between rip and cutter (requires an Ethernet crossover cable).

Try the USB connection (make sure to change the connection type in VisualCut to USB)

 

USB connected:

USB_Connection.png

Make sure to use a USB cable shorter than 10ft. Longer cables could cause issues even if they worked before.

Configure VisualCut to either USB or Ethernet (based on the connection)

In case of a USB connected cutter, try a different USB port? Try with or without a powered USB hub.

Is the Summa visible under the under the Caldera Server Admin > Devices > USB Tab

Summa_Devices.png

Try using the Ethernet connection. Ethernet is preferred especially with longer rip to cutter connections.

 

Either Connection:

Check if cutter language is set to DM/PL (This is a setting on the cutter itself).

MENU -> SYSTEM SETUP -> EMULATE -> DM/PL

 