Colex SharpCut / OptiScout – Methods and Materials Not Synchronizing

Issue

CalderaRIP cannot synchronize methods and materials with the SharpCut or OptiScout PC controller.

 

Problem

Synchronization requires the OXF interface port to be configured.

 

Solution

  1. In the SharpCut/OptiScout PC controller, set the Port number for the OXF interface to 52000:
    Capture_d_e_cran_2021-07-09_a__17_06_18_png.png
  2. In CalderaRIP, open the Cutter Parameters. 
  3. In the Hostname field, enter the IP address of the OptiScout PC controller followed by :52000 (Example: 192.168.1.100:52000): 
    Cutter_parameters.png
  4. Once configured, methods and materials will synchronize automatically:
    Capture_d_e_cran_2021-07-09_a__17_05_19_png.png

    Capture_d_e_cran_2021-07-09_a__17_05_00_png_et_Optiscout-Connected-How_to_synchronize_methods_and_materials.png